Be sure to thoroughly read the owner’s manual and warranty.
Leak on suction side of system: On shallow well units, install pressure gauge on suction side. When experiencing a pump failure, check installation to see if pump has been Motor wired incorrectly, Check wiring diagram, Reconnect for proper voltage Leak on discharge side of system, On shallow well units, install. you for choosing Everbilt!
. Please carefully read the manual and follow the This unit is a single stage jet pump designed for shallow water well applications, .
Please read and understand this entire manual before attempting to assemble, Pump Electrical Connections. .
Shallow well jet pumps are designed for use. Get Everbilt JA3 Instructions / Assembly.
Get all Everbilt manuals! USE AND CARE GUIDE SHALLOW WELL JET PUMP SKU # , SKU the manual and follow the instructions regarding common pump problems and remedies.
Jet Pump Troubleshooting
If the water level to the pump is deeper than 25 ft., a convertible jet pump or a.SHALLOW WELL JET PUMP MODEL # ES05S, EK05S, CPH05S, ES07S, EK07S, ES10S, EK10S, JHU15S IL motor nameplate and wiring diagrams and check voltage of power supply. 5.
Unit must be securely and adequately Shallow well jet pumps are designed for use where the suction lift is 25 feet or less. They can.
Pre-Installation APPLICATION This unit is a single stage jet pump designed for shallow water well applications, where the water level is less than 25 ft. deep. If the water level to the pump is deeper than 25 ft., a convertible jet pump or a deep well submersible pump should be used.
can suck air, the pump will not be able to pull water from the well. Step 3.
Adjust the pump mounting height so that the plumbing connections do not put a strain on the pump body. Support the pipe so that the pump body does not take the weight of piping or fittings.
You have just completed the well plumbing for your new shallow well jet pump. Shallow Well Jet Pump Troubleshooting.
Well Jet Pumps and Adjusting Pressure Switches
Possible Cause. Corrective Action.
LITTLE OR NO DISCHARGE. Casing not initially filled with water.
Fill pump casing. Check wiring diagram. Casing gasket leaking. Replace. Suction or discharge line valves closed. Open.
PUMP WILL NOT DELIVER WATER OR DEVELOP PRESSURE. A shallow well jet pump’s pressure switch regulates the amount time the pump motor runs. A well’s pressure switch turns on the jet pump once the water pressure in the storage tank’s bladder drops below a set low-limit and turns off the jet pump once the water pressure breaks the high-limit setting.Jet Pump TroubleshootingShallow Well Jet Pump Troubleshooting – Flint & Walling Products